1
/
of
1
Command Access
Command Access MLRK1-YAL6 Motorized Latch Retraction Kit — For Accentra (formerly Yale) 6000 Series (Field Install, UL, 3-Year Warranty)
Command Access MLRK1-YAL6 Motorized Latch Retraction Kit — For Accentra (formerly Yale) 6000 Series (Field Install, UL, 3-Year Warranty)
Regular price
$495.00 USD
Regular price
Sale price
$495.00 USD
Shipping calculated at checkout.
Quantity
Couldn't load pickup availability
Upgrade Accentra/Yale 6000 Exit Devices to Motor-Driven Latch Retraction
The Command Access MLRK1-YAL6 is a field-install motorized latch retraction kit that converts Accentra (formerly Yale) 6000 Series exit devices from mechanical to electrified pullback while maintaining listings. Install in minutes, Built-in REX, and fine-tune with Push-to-Set (PTS). Powered by the MM4S Smart Module for onboard diagnostics and efficient power management. UL Listed and backed by a 3-year “no hassle” warranty.
Why installers choose MLRK1-YAL6
- Fast, quiet, smooth & strong motor performance.
- Drop-in field kit with minimal modification; quick wire raceway.
- PTS one-touch post-install fine adjustment (≈ 1/4").
- MM4S Smart Module with onboard diagnostics and audible feedback.
- Standard-torque mode capable of pulling difficult/tall vertical-rod doors.
- Electric dogging rated for continuous duty; auto re-engages if the pushpad is pulled.
- Built-in REX for request-to-exit integration.
- UL Listed with a 3-year warranty.
Compatibility
Works with all Accentra (formerly Yale) 6000 Series exit devices.
Specifications
Voltage Range | 24–28 VDC (over-voltage protection: unit shuts down > 28 VDC) |
---|---|
Current (Standard) | Peak ≈ 900 mA; Hold ≈ 215 mA |
Control Module | MM4S Smart Module with onboard diagnostics |
Modes | Standard-torque; energy-conscious yet capable for tough doors |
PTS Adjustment | ≈ 1/4″ |
Request-to-Exit | Built-in REX |
Wire Run | Up to 300′ with 18 AWG |
Cutdown Details | 36″/48″ rails — 6.5″ filler plate required |
Duty Rating | Electric dogging rated continuous; auto re-engage if pushpad is pulled |
Listings | UL Listed |
Warranty | 3-Year “No Hassle” Warranty |
Installer Notes
- Confirm device series/handing and rail cut length before energizing.
- Use a regulated 24 VDC supply sized for inrush; verify 24–28 VDC at the rail under load.
- Route cabling to avoid pinch points; secure the raceway.
- If adding REX, wire to your access control panel per required input type.
What’s Included
MLRK1-YAL6 motor kit with MM4S module, hardware, and installation instructions with built-in REX.
Share